1.
Braz. dent. j ; 25(1): 12-16, Jan-Feb/2014. tab
Article in English | LILACS | ID: lil-709394

ABSTRACT

The aim of this study was to compare in vivo the accuracy of two electronic foramen locators (EFLs) based on different operation systems - Root ZX and Propex II. Ten healthy adult patients needing premolar extractions due to orthodontic reasons participated in the study, providing a sample of 17 noncarious, non-restored, vital teeth (n= 24 canals). After coronal access preparation and cervical preflaring and prior to tooth extraction, the root canal length was measured alternating the two EFLs. All measurements were performed with K-files well fitted to the canal diameter at the level that each EFL indicated the apical foramen in their display (APEX or 0.0). The last K-file were fixed in place with cyanoacrylate, the tooth was extracted, and the apical 4 mm of each root were resected to measure the distance between the file tip and the apical foramen. The mean errors based on the absolute values of discrepancies were 0.30 ± 0.29 mm (Root ZX) and 0.32 ± 0.27 mm (Propex II). Analysis by the Wilcoxon test for paired samples showed no statistically significant differences between the electronic canal measurements performed with the EFLs (p=0.587). The apical foramen was accurately located in 75% (Root ZX) and 66.7% (Propex II) of the cases, considering a ±0.5 mm error margin, with no statistically significant difference by the chi-square test. Despite having different measurement mechanisms, both EFLs were capable of locating the apical foramen with high accuracy in vivo. Under the tested clinical conditions, Root ZX and Propex II displayed similar results.


O presente estudo teve como objetivo avaliar, in vivo, a precisão de dois localizadores eletrônicos foraminais (LEFs) baseados em diferentes mecanismos de funcionamento, Root ZX e Propex II, na determinação do forame apical, sendo utilizados nos mesmos dentes. Após o acesso coronário e o pré-alargamento, e anteriormente à exodontia, os comprimentos de 24 canais radiculares foram determinados eletronicamente alternando-se os dois LEFs. As odontometrias foram realizadas até que os dispositivos apontassem o FA (APEX), utilizando-se limas tipo-K ajustadas. O último instrumento utilizado foi fixado em posição, o dente extraído e os 4,0 mm apicais de cada canal desgastados de forma a possibilitar a determinação da distância entre a ponta dos instrumentos e o forame apical. Os erros médios em função dos valores absolutos das discrepâncias foram, respectivamente, 0,30 ± 0,29 mm (Root ZX) e 0,32 ± 0,27 mm (Propex II). A análise estatística realizada por meio do teste de Wilcoxon para amostras pareadas demonstrou a semelhança entre as determinações do forame apical realizadas pelos dois LEFs (p=0,587). O comprimento radicular até o forame apical foi corretamente determinado em 75% (Root ZX) e 66,7% (Propex II) dos casos, considerando margem de ± 0,5 mm, sem diferenças estatísticas quando analisados pelo teste qui-quadrado. Os LEFs avaliados e consequentemente seus mecanismos de funcionamento, foram capazes de determinar o comprimento dos canais radiculares com precisão em condições in vivo. Nas condições do presente estudo, Root ZX e Propex II apresentaram resultados semelhantes.


Subject(s)
Adolescent , Adult , Humans , Young Adult , Electronics , Root Canal Therapy , Tooth Extraction
2.
Braz. dent. j ; 23(6): 703-706, 2012. ilus, tab
Article in English | LILACS | ID: lil-662430

ABSTRACT

The aim of this study was to assess the applicability of gray scale inversion in performing digital linear endodontic measurements. Standardized digital images were taken of 40 extracted human permanent single-rooted teeth with K-files size 15 placed at different lengths in the root canal, using the CDR Wireless® digital system. All images were treated with Positive, a digital tool that inverts the grayscale value. Eight radiologists measured the distance between the lower limit of the rubber stop and the tip of the file on both original and positive images. After 15 days, they repeated this procedure in 50% of the image samples. The intra- and inter-examiner agreement was analyzed by intraclass correlation test, and the comparison between the two image groups and the actual lengths by the Student's t-test (α=0.05). Intra- and inter-examiner evaluation showed high reproducibility (r>0.95) of both original and positive images. No statistically significant differences (p>0.05) were found between measurements performed on original and positive images, but both differed significantly from the actual lengths (p<0.05). Gray scale inversion has low applicability in measuring endodontic files, since it did not improve the accuracy of measurements.


O objetivo deste estudo foi avaliar a aplicabilidade da inversão da escala de cinza na realização de mensurações endodônticas lineares digitais. Quarenta dentes unirradiculares humanos extraídos foram radiografados com limas K tamanho 15 posicionadas no canal radicular em diferentes comprimentos, usando o sistema digital CDR Wireless®. Todas as imagens foram tratadas com Positive, uma ferramenta digital que inverte os valores da escala de cinza. Oito radiologistas mediram a distância entre o limite inferior do stop de borracha e a ponta da lima endodôntica nas imagens originais e positivas. Após quinze dias, eles repetiram esse procedimento em 50% da amostra. A concordância intra- e interobservador foi analisada pelo teste de correlação intraclasse e a comparação entre os dois grupos de imagem e os valores reais, pelo teste t-Student (α=0,05). A análise intra- e interobservador apresentou elevada reprodutibilidade (r>0,95) das imagens original e Positive. Não foi encontrada diferença (p>0,05) entre as medidas realizadas nas imagens original e positiva, mas ambas diferiram dos valores reais (p<0,05). A inversão da escala de cinza tem baixa aplicabilidade na realização de mensuração endodôntica, considerando que as medidas não se apresentaram mais acuradas.


Subject(s)
Humans , Dental Pulp Cavity , Odontometry/methods , Radiography, Dental, Digital/methods , Tooth Apex , Dental Pulp Cavity/anatomy & histology , Image Processing, Computer-Assisted/methods , Image Processing, Computer-Assisted/statistics & numerical data , Observer Variation , Odontometry/statistics & numerical data , Phantoms, Imaging , Reproducibility of Results , Radiography, Dental, Digital/statistics & numerical data , Root Canal Preparation/instrumentation , Software , Tooth Apex/anatomy & histology